COOLING CAPACITY RESTORED TO MAXIMUM PERFORMANCE WITH BOX COOLER PERFORMANCE PLAN
When your box cooler is fouled by marine growth (built-up algae or barnacles, for example), this ultimately affects its cooling capacity, which can be restored with our box cooler performance plan. CP Heat Exchanger Technologies developed a program to renew your box cooler and restore its performance. Within this program the box cooler will be treated with a special cleaning method, a sandblast treatment and multiple layers of coating will be applied. Optionally we can overhaul your box cooler or perform repairs. This renewal program ensures a complete restore of the cooling capacity and bring your box cooler back to its maximum performance.
ULTIMATE PROTECTION: PHENOL COATING & ANTIFOULING
Within the box cooler performance plan the cooler will be treated with three layers of phenol coating. This coating protects the cooler against corrosion. Additional, an extra layer of antifouling can be applied. The antifouling coating minimizes accretation of marine organisms and is therefore perfectly suitable for vessels that sail in shallow, warm waters at lower speeds. A combination of both type of coatings will give your cooler the ultimate protection.
MAINTENANCE AND REPAIR OF BOX COOLERS
If desired, we can also overhaul your box cooler. The following maintenance will be performed:
- Disassembly, cleaning and assembly of covers
- Installation of new gaskets
- Replacement of nuts and bolts
- Application of a new coat of paint to the covers
- Threading and wire-brushing of tube plates
- Pressure testing
Interested? Call us!
Additional we can also replace damaged tubes (retubing). Are you interested in more information about our services or the box cooler performance plan? Please feel free to give us a call at + 31 10 4296104.


BOX COOLER RENEWAL TREATMENT

PRE-CLEANING TREATMENT
At arrival in the workshop, the box cooler receives a pre-cleaning treatment in which the outer pollution will be removed. After pre-cleaning the cooler will be cleaned under high-pressure.

CHEMICAL CLEANING TREATMENT
The box cooler goes in the chemical bath where the inner surfaces are rinsed. The last contamination will be removed during the high-pressure water jetting, after the chemical procedure is finished.

GRIT BLAST TREATMENT
When the cleaning procedure is fully completed, the cooler is being grit blasted to get the best coating results.

COATING
After sandblasting, the cooler will be treated with three layers of phenol coating. Additional, an extra layer of antifouling can be applied.